Download RSLogix Micro Starter Lite: A Free Programming Software for MicroLogix PLCs
If you are looking for a free and easy way to program your MicroLogix PLCs, you might want to check out RSLogix Micro Starter Lite. This software is a scaled-down version of the full-featured RSLogix Micro software, but it still allows you to create, edit, and monitor ladder logic programs for your MicroLogix 1000 and 1100 controllers. In this article, we will show you what RSLogix Micro Starter Lite is, how to download it, and how to use it with RSLogix Emulate 500 to simulate your PLC programs.
What is RSLogix Micro Starter Lite?
RSLogix Micro Starter Lite is a free programming software for MicroLogix PLCs developed by Rockwell Automation. It is based on the same user interface and functionality as the RSLogix 500 software, which is used for programming SLC 500 and MicroLogix PLCs. However, RSLogix Micro Starter Lite only supports two models of MicroLogix controllers: the MicroLogix 1000 and the MicroLogix 1100.
download rslogix micro starter lite
Features and benefits of RSLogix Micro Starter Lite
Some of the features and benefits of using RSLogix Micro Starter Lite are:
It is free to download and use, no license or activation required.
It allows you to create, edit, monitor, and troubleshoot ladder logic programs for your MicroLogix PLCs.
It supports online editing, which means you can make changes to your program while it is running on the PLC.
It has a built-in instruction set reference that provides detailed information on each instruction and its syntax.
It has a drag-and-drop feature that lets you easily insert instructions, symbols, comments, and rungs into your program.
It has a data monitor tool that lets you view and modify the values of data files, timers, counters, inputs, outputs, and other elements in your program.
It has a search and replace tool that lets you quickly find and modify specific elements in your program.
It has a password protection feature that lets you secure your program from unauthorized access or modification.
Limitations and requirements of RSLogix Micro Starter Lite
Some of the limitations and requirements of using RSLogix Micro Starter Lite are:
It only supports two models of MicroLogix controllers: the MicroLogix 1000 and the MicroLogix 1100. If you need to program other models of MicroLogix or SLC 500 controllers, you will need to purchase the full version of RSLogix Micro or RSLogix 500 software.
It does not support advanced features such as function block diagram (FBD), structured text (ST), or sequential function chart (SFC) programming languages. It only supports ladder logic (LD) programming language.
How to download RSLogix Micro Starter Lite?
Downloading RSLogix Micro Starter Lite is a simple and straightforward process. You just need to follow these steps:
Step 1: Navigate to the Rockwell Automation website
The first step is to go to the Rockwell Automation website, which is the official source of RSLogix Micro Starter Lite and other software products from the same company. You can use this link to access the website: [Rockwell Automation](^1^).
Step 2: Search for the product by model number
The next step is to search for the product by its model number, which is 9324-RLM0100ENE. You can use the search box on the top right corner of the website, or you can use this link to go directly to the product page: [RSLogix Micro Starter Lite](^2^).
Step 3: Select the version and click on the download button
The product page will show you different versions of RSLogix Micro Starter Lite that are available for download. You can choose the latest version, which is 12.03.00 as of June 2023, or you can choose an older version if you prefer. Once you select the version, you will see a download button on the right side of the page. Click on it to proceed.
Step 4: Sign in or create a free account
Before you can download the software, you will need to sign in or create a free account with Rockwell Automation. If you already have an account, you can enter your email and password and click on "Sign In". If you don't have an account, you can click on "Create Account" and fill in your details. You will need to provide your name, email, country, company name, and industry. You will also need to agree to the terms and conditions and privacy policy of Rockwell Automation.
Step 5: Accept the end user license agreement
After signing in or creating an account, you will see a pop-up window that shows you the end user license agreement (EULA) for RSLogix Micro Starter Lite. You will need to read and accept the EULA before you can download the software. To accept the EULA, check the box that says "I agree" and click on "Accept".
How to download rslogix micro starter lite for free
RSLogix micro starter lite tutorial
RSLogix micro starter lite vs developer
RSLogix micro starter lite system requirements
RSLogix micro starter lite activation
RSLogix micro starter lite with rslogix emulate 500
RSLogix micro starter lite windows 10 compatibility
RSLogix micro starter lite software download
RSLogix micro starter lite user manual
RSLogix micro starter lite ladder logic examples
RSLogix micro starter lite online training
RSLogix micro starter lite installation guide
RSLogix micro starter lite supported controllers
RSLogix micro starter lite update
RSLogix micro starter lite license key
RSLogix micro starter lite plc programming software
RSLogix micro starter lite rockwell automation
RSLogix micro starter lite product notice
RSLogix micro starter lite download instructions
RSLogix micro starter lite version history
RSLogix micro starter lite troubleshooting
RSLogix micro starter lite features and benefits
RSLogix micro starter lite serial number
RSLogix micro starter lite demo mode
RSLogix micro starter lite help file
RSLogix micro starter lite project file format
RSLogix micro starter lite communication settings
RSLogix micro starter lite offline simulation
RSLogix micro starter lite import/export options
RSLogix micro starter lite data monitor tool
RSLogix micro starter lite compare tool
RSLogix micro starter lite backup and restore utility
RSLogix micro starter lite password protection
RSLogix micro starter lite function block diagram editor
RSLogix micro starter lite instruction set reference manual
RSLogix micro starter lite release notes
RSLogix micro starter lite customer reviews and ratings
RSLogix micro starter lite alternative software solutions
RSLogix micro starter lite technical support and contact information
RSLogix micro starter lite frequently asked questions and answers
Step 6: Choose the direct download or download manager option
The next step is to choose how you want to download the software. You have two options: direct download or download manager. The direct download option will let you download the software as a single file, which is about 1 GB in size. The download manager option will let you download the software as multiple smaller files, which can be faster and more reliable. You can also pause and resume your download with this option. To choose an option, click on the radio button next to it and click on "Download".
Step 7: Run the installer and follow the instructions
The final step is to run the installer and follow the instructions on your screen. Depending on your option, you will either have one file or multiple files to run. If you have multiple files, you will need to run them in order from 1 to 5. The installer will guide you through the installation process, which may take several minutes. You will need to agree to another EULA, choose a destination folder, and select some options for your installation. Once the installation is complete, you will be able to launch RSLogix Micro Starter Lite from your start menu or desktop. How to use RSLogix Micro Starter Lite with RSLogix Emulate 500?
One of the advantages of using RSLogix Micro Starter Lite is that you can use it with RSLogix Emulate 500, which is a software emulator that simulates the operation of a PLC. This means that you can test and debug your PLC programs without having a physical PLC connected to your computer. You can also save time and money by avoiding the need to purchase and wire up a PLC and its peripherals. In this section, we will show you how to use RSLogix Micro Starter Lite with RSLogix Emulate 500 to create and run a simulation project.
What is RSLogix Emulate 500?
RSLogix Emulate 500 is a software emulator that mimics the behavior of a PLC. It runs on your computer and communicates with RSLogix Micro Starter Lite via a virtual backplane. It supports the same instruction set and data files as the real PLC, and it can execute your ladder logic programs as if they were running on the PLC. You can also monitor and modify the values of inputs, outputs, timers, counters, and other elements in your program using RSLogix Micro Starter Lite.
How to install and configure RSLogix Emulate 500?
To install and configure RSLogix Emulate 500, you will need to follow these steps:
Step 1: Download RSLogix Emulate 500
The first step is to download RSLogix Emulate 500 from the Rockwell Automation website. You can use this link to access the product page: [RSLogix Emulate 500]. You will need to sign in or create a free account, accept the EULA, and choose the direct download or download manager option, just like you did for RSLogix Micro Starter Lite. The file size is about 300 MB.
Step 2: Run the installer and follow the instructions
The next step is to run the installer and follow the instructions on your screen. The installer will guide you through the installation process, which may take several minutes. You will need to agree to another EULA, choose a destination folder, and select some options for your installation. Once the installation is complete, you will be able to launch RSLogix Emulate 500 from your start menu or desktop.
Step 3: Configure the virtual backplane
The final step is to configure the virtual backplane, which is a software component that allows RSLogix Emulate 500 and RSLogix Micro Starter Lite to communicate with each other. To configure the virtual backplane, you will need to follow these steps:
Open RSLogix Emulate 500 and click on "Tools" > "Virtual Backplane".
A window will pop up that shows you the available slots for emulated devices. You will see that slot 0 is occupied by an Ethernet module, which is used for communication with your computer.
Right-click on slot 1 and select "Create Module". A dialog box will appear that lets you choose the type of module you want to create.
Select "Emulated SLC/Micro Chassis" from the drop-down menu and click on "OK". A new module will appear in slot 1 with a default name of "Emulator_01".
Right-click on slot 1 again and select "Properties". A dialog box will appear that lets you change the name and model of the emulated device.
Change the name to something meaningful, such as "MicroLogix_1100". Then, change the model to match the type of PLC you want to emulate. For example, if you want to emulate a MicroLogix 1100 controller with 16 digital inputs and 16 digital outputs, select "1763-L16BWA" from the drop-down menu.
Click on "OK" to save your changes. You have now configured your virtual backplane with an emulated PLC in slot 1.
How to create and run a simulation project with RSLogix Micro Starter Lite and RSLogix Emulate 500?
To create and run a simulation project with RSLogix Micro Starter Lite and RSLogix Emulate 500, you will need to follow these steps:
Step 1: Create a new project in RSLogix Micro Starter Lite
The first step is to create a new project in RSLogix Micro Starter Lite. To do this, open RSLogix Micro Starter Lite and click on "File" > "New". A dialog box will appear that lets you choose the type of controller and the name of the project. Select "MicroLogix 1100" from the drop-down menu and enter a name for your project, such as "Simulation_Project". Click on "OK" to create your project.
Step 2: Write your ladder logic program in RSLogix Micro Starter Lite
The next step is to write your ladder logic program in RSLogix Micro Starter Lite. You can use the drag-and-drop feature to insert instructions, symbols, comments, and rungs into your program. You can also use the data monitor tool to view and modify the values of data files, timers, counters, inputs, outputs, and other elements in your program. You can use the search and replace tool to quickly find and modify specific elements in your program. You can also use the password protection feature to secure your program from unauthorized access or modification.
For example, you can write a simple program that turns on an output when an input is activated. To do this, you can follow these steps:
Click on the "Main Program" tab on the left side of the screen. This is where you will write your ladder logic program.
Click on the "Rung" icon on the toolbar. This will insert a new rung into your program.
Click on the "Examine On" icon on the toolbar. This will insert an instruction that checks if an input is on or off.
Click on the address box of the instruction and enter "I:0/0". This will assign the address of the first input of the PLC to the instruction.
Click on the "Output Energize" icon on the toolbar. This will insert an instruction that turns on or off an output.
Click on the address box of the instruction and enter "O:0/0". This will assign the address of the first output of the PLC to the instruction.
Click on the "Accept" icon on the toolbar. This will save your changes and verify your program for any errors.
You have now written a ladder logic program that turns on output O:0/0 when input I:0/0 is on.
Step 3: Configure the communication settings in RSLogix Micro Starter Lite
The next step is to configure the communication settings in RSLogix Micro Starter Lite. This will allow you to connect to RSLogix Emulate 500 and download your program to the emulated PLC. To do this, you can follow these steps:
Click on "Communications" > "System Comms". A window will pop up that shows you the available communication paths.
Expand the "Virtual Backplane" node and select "Emulator_01 - MicroLogix_1100". This is the emulated PLC that you configured in RSLogix Emulate 500.
Click on "OK" to close the window and select the communication path.
Step 4: Download your program to RSLogix Emulate 500
The final step is to download your program to RSLogix Emulate 500. This will transfer your program from RSLogix Micro Starter Lite to the emulated PLC. To do this, you can follow these steps:
Click on "Communications" > "Download". A dialog box will appear that asks you to confirm your action.
Click on "Yes" to proceed with the download. A progress bar will show you the status of the download.
When the download is complete, a dialog box will appear that asks you if you want to go online with RSLogix Emulate 500.
Click on "Yes" to go online with RSLogix Emulate 500. This will establish a connection between RSLogix Micro Starter Lite and RSLogix Emulate 500, and allow you to monitor and edit your program while it is running on the emulated PLC.
Conclusion
In this article, we have shown you how to download RSLogix Micro Starter Lite, a free programming software for MicroLogix PLCs. We have also shown you how to use it with RSLogix Emulate 500, a software emulator that simulates the operation of a PLC. By using these two software products together, you can create, edit, monitor, and troubleshoot ladder logic programs for your MicroLogix PLCs without having a physical PLC connected to your computer. You can also save time and money by avoiding the need to purchase and wire up a PLC and its peripherals. We hope that this article has been helpful and informative for you. If you have any questions or feedback, please feel free to leave a comment below. Thank you for reading!
FAQs
Here are some frequently asked questions about RSLogix Micro Starter Lite and RSLogix Emulate 500:
Q: What are the system requirements for RSLogix Micro Starter Lite and RSLogix Emulate 500?
A: According to the Rockwell Automation website, the minimum system requirements for RSLogix Micro Starter Lite and RSLogix Emulate 500 are as follows:
Component
Requirement
Operating system
Windows 7, 8.1, or 10 (32-bit or 64-bit)
Processor
Intel Pentium 4 or equivalent
Memory
2 GB RAM or more
Hard disk space
2 GB or more for RSLogix Micro Starter Lite500 MB or more for RSLogix Emulate 500
Display resolution
1024 x 768 or higher
Internet connection
Required for downloading and registering the software products
Q: How can I get technical support for RSLogix Micro Starter Lite and RSLogix Emulate 500?
A: You can get technical support for RSLogix Micro Starter Lite and RSLogix Emulate 500 from the Rockwell Automation website. You can use this link to access the support page: [Rockwell Automation Support]. You can also contact the Rockwell Automation customer service by phone or email. You can use this link to find the contact information for your region: [Rockwell Automation Contact Us].
Q: How can I learn more about RSLogix Micro Starter Lite and RSLogix Emulate 500?
A: You can learn more about RSLogix Micro Starter Lite and RSLogix Emulate 500 from the Rockwell Automation website. You can use these links to access the product pages, where you can find user manuals, tutorials, videos, and other resources:
- [RSLogix Micro Starter Lite] - [RSLogix Emulate 500] Q: How can I upgrade to the full version of RSLogix Micro or RSLogix 500?
A: If you want to upgrade to the full version of RSLogix Micro or RSLogix 500, you will need to purchase a license from Rockwell Automation. You can use these links to access the product pages, where you can find pricing and ordering information:
- [RSLogix Micro] - [RSLogix 500] Q: How can I connect a physical PLC to my computer using RSLogix Micro Starter Lite?
A: If you want to connect a physical PLC to your computer using RSLogix Micro Starter Lite, you will need a communication cable and a communication driver. The type of cable and driver depends on the model of your PLC and the port of your computer. For example, if you have a MicroLogix 1100 controller with an Ethernet port and a computer with an Ethernet port, you will need an Ethernet cable and an Ethernet/IP driver. You can use this link to find the compatible cables and drivers for your PLC: [Rockwell Automation Compatibility & Downloads]. Once you have the cable and driver, you can connect your PLC to your computer and configure the communication settings in RSLogix Micro Starter Lite. 44f88ac181